UV flatbed printer installation site requirements

         UV flatbed printer installation site requirements mainly include seven aspects, which are light, temperature, airflow, power, wiring, ground, and dust requirements. During the installation process, strictly follow the standards to ensure the smooth installation and use of the machine.

UV flatbed printer installation site requirements mainly include seven aspects, which are light, temperature, airflow, power, wiring, ground, and dust requirements. During the installation process, strictly follow the standards to ensure the smooth installation and use of the machine.     1. Ambient light requirements:  UV ink contains UV curing agent. Natural light in the working environment or LED UV light will cause the ink to solidify. In order to extend the life of the print head, UV flat printers need to take measures to avoid natural light on the scene. Energy saving lamps provided.  2. Ambient temperature requirements:  The recommended temperature for the storage and use of UV ink is 18 to 25 degrees Celsius, and the humidity is controlled from 55% to 65%. Avoid fire sources and high heat environments, and pay attention to the safety of the storage and use environment.  3. Ambient airflow requirements:     UV ink will have a slightly irritating odor. Please take good ventilation measures in a closed environment. If auxiliary heating or air circulation equipment is on site, the air flow generated by such equipment cannot be directed to the UV flatbed printer table.  Fourth, environmental dust requirements:     Too much dust and swarf in the UV machine working environment may cause board circuit failure and nozzle blockage, which will seriously cause ink dusting, affect printing results, and damage the nozzle. Please do on-site cleaning.  V. On-site power requirements:     The UV flatbed printer should provide a standard AC voltage of 220V / 50HZ on site, and the voltage requirement should fluctuate less than 2.5%. The line should include a reliable ground wire and the resistance of the lead to ground should be less than 4 ohms. It needs to be equipped with an independent power system, and cannot be mixed with other equipment.  6. On-site wiring requirements:  Please use wire trunking uniformly for field wiring of uv flatbed printers. Equipment communication and power lines must not be stepped on. If you go to the ground, you need to install a special protective shell on the line to prevent the wire from wearing out and leaking electricity after a long time.  Ground requirements:     The floor where the UV flatbed printer is installed should be flat, and there should be no landslides, depressions, etc., which will affect the normal operation of the equipment in the later stage.

         1. Ambient light requirements:

         UV ink contains UV curing agent. Natural light in the working environment or LED UV light will cause the ink to solidify. In order to extend the life of the print head, UV flat printers need to take measures to avoid natural light on the scene. Energy saving lamps provided.

         2. Ambient temperature requirements:

         The recommended temperature for the storage and use of UV ink is 18 to 25 degrees Celsius, and the humidity is controlled from 55% to 65%. Avoid fire sources and high heat environments, and pay attention to the safety of the storage and use environment.

          3. Ambient airflow requirements:

          UV ink will have a slightly irritating odor. Please take good ventilation measures in a closed environment. If auxiliary heating or air circulation equipment is on site, the air flow generated by such equipment cannot be directed to the UV flatbed printer table.

         4.environmental dust requirements:

         Too much dust and swarf in the UV machine working environment may cause board circuit failure and nozzle blockage, which will seriously cause ink dusting, affect printing results, and damage the nozzle. Please do on-site cleaning.

         5. On-site power requirements:

         The UV flatbed printer should provide a standard AC voltage of 220V / 50HZ on site, and the voltage requirement should fluctuate less than 2.5%. The line should include a reliable ground wire and the resistance of the lead to ground should be less than 4 ohms. It needs to be equipped with an independent power system, and cannot be mixed with other equipment.

         6. On-site wiring requirements:

         Please use wire trunking uniformly for field wiring of uv flatbed printers. Equipment communication and power lines must not be stepped on. If you go to the ground, you need to install a special protective shell on the line to prevent the wire from wearing out and leaking electricity after a long time.

         Ground requirements:

        The floor where the UV flatbed printer is installed should be flat, and there should be no landslides, depressions, etc., which will affect the normal operation of the equipment in the later stage.