UV flatbed printer XYZ axis cannot be reset

        uv flatbed printer cannot reset the XYZ axis directly will cause the machine to print normally. It needs to be distinguished that the fault of the XY axis is connected, but the reason why the Z axis cannot reset is different from the XY axis. The X axis refers to the abscissa direction of the device, the Y axis refers to the vertical coordinate direction of the device, and the Z axis refers to the height direction of the device.

20191204142033_49784

        1.The XY axis of UV flatbed printer cannot be reset

        A. The limit is exceeded, the solution can be pushed back to the trolley of the device;

        B. The emergency stop switch is not turned on. The solution is to turn on the emergency stop switch.

        C. Single driver is powered off, the solution is to power on again, if it is damaged, replace it with a new single driver;

        D. The driver and power supply are damaged. The solution is to replace the new driver and power supply.

        E. The communication is abnormal and the optical fiber is damaged. The solution is to replace the new optical fiber cable.

        F. The relay is damaged or has poor contact. The solution is to replace the new relay. If the contact is poor, tighten and reinforce it.

        2.The Z axis of UV flatbed printer cannot be reset

       A. Overrun or stuck, just push the z-axis back to the limited range;

       B. The communication is abnormal and the optical fiber is damaged.

       C. The screw joint of the motor is loose. Click the screw joint to tighten the solution.

       D. The motor driver is not in good contact. The solution is to tighten the motor driver interface.

       E. The driver signal cable is loose. The solution is to tighten the connector of the driver signal cable.

cache